Aqua Master Tools | Eich solution EC 14.13 ms/cm | 100 ml

buffer-soution-ec-14

Aqua Master Tools | Eich solution EC 14.13 ms/cm | 100 ml

7,00 

In stock
0 out of 5

7,00 

  • calibration solution with an EC value of 14.13 ms/cm
  • Returned to nest standard
  • calibration of EC measuring devices
  • Ensuring a precise EC value measurement of nutrient solutions
Availability: 14 vorrätig Artikelnummer: am-020 Kategorie: Schlagwort:
Compare

Beschreibung

Buffer solution EC 14.13 (25 ° C) – calibration solution for your EC measuring device

In hydroponic plant breeding, monitoring the electrical conductivity (EC value) plays an important role in your nutrient solution. The EC value provides information about the amount of dissolved salts in the nutrient solution and thus influences the growth and development of your plants. In order to measure the EC value of nutrient solutions, EC measuring devices such as the EC measuring device E50 Pro from aqua master tools . An important prerequisite for precise EC measurement is the correct calibration of the EC probe with a calibration fluid. For this purpose, the EC probe is immersed in the buffer solution and the display is set to the EC value of 3000 µs/cm. This ensures that the measuring device displays the EC value correctly.

buffer solution EC 14.13 as a calibration fluid

With a electrical conductivity of 14.13 ms/cm at 25 ° C it is suitable to oak EC probes. This enables an precise measurement of the EC value of the nutrient solution and thus also correct monitoring of the growth process of your plants.

precautionary measures when using buffer solution EC 14.13

It is important to note that the EC 14.13 buffer solution contains a chemical connection and can become unusable in improper handling. For example, it is recommended to close the bottle again immediately after use and keep it at room temperature. After use, the bottle should be closed again immediately and the buffer solution should not be returned to the container. This prevents the solution from contamination.

nist standard

Due to their returnable conformity to the nest standard (National Institute of Standards and Technology) and their usability for the calibration of EC measuring devices, it can be ensured that the measurements are precise and reliable.

  • 15 (° C): 1147 µs/cm
  • 20 (° C): 1278 µs/cm
  • 21 (° C): 1305 µs/cm
  • 22 (° C): 1332 µs/cm
  • 23 (° C): 1359 µs/cm
  • 24 (° C): 1386 µs/cm
  • 25 (° C): 1413 µs/cm
  • 26 (° C): 1440 µs/cm
  • 27 (° C): 1467 µs/cm
  • 28 (° C): 1494 µs/cm
  • 29 (° C): 1521 µs/cm
  • 30 (° C): 1548 µs/cm

included in the scope of delivery:

  • 1x buffer solution EC 14.13, 100 ml

Zusätzliche Informationen

Gewicht0,12 kg
Größe10 × 5 × 5 cm